Nine steps to use the sterilizer

1. Switch on the switchboard and verify that the voltage is within 380V ± 10%: If the switch cannot be turned on, check the supply voltage. The state selection switch is placed in the running position, and the blow control is activated. If it cannot be activated, check the alarm prompt and troubleshoot.

2. Open the compressed air shutoff valve associated with the control panel and maintain the pressure at 7-9 bar. Note that the compressed air shut-off valve is opened for a short time to ensure water and impurities.

3. Check if the waterway is running well, and whether the pipeline opens the shutoff valve to supply water to the equipment.

4. Check if the compressed air of the control panel of the tube killer is in a normal state.

5. Check the filling water condition for the superheated water circulation so that the water level entering the buffer tank is between the two calibrations, and the pressure is between 1 and 1.5 bar. If the pressure is wrong: Adjust the input and output translation valves on the top of the buffer tank until the pressure is correct.

6. The barrel level is low: During the cycle operation, open the valve that inputs the condensate until the barrel reaches the correct level (30%-40%).

7. The buffer tank level is too high: when the circulation pump is running, use the manual drain valve drainage method to reach the correct liquid level.

8. Open the shut-off valve of the pneumatic regulating valve of the sterilization pot to determine the steam pressure within the range of 6±1 bar. If it cannot be reached, check the boiler and steam pipe network, then open the near-steam drain valve drain and impurities, and open the steam manual intake valve, but Cannot open the bypass.

9. Check if the steam shielding pipe is unobstructed. If it does not work, quickly open it with compressed air.